Subject to changes due to technical improvements ESS Energie Systeme & Service GmbH
14 CHP accessory range – 01/2010
5368 463
2.3.2 Plinth
Article number CHP module type ESS Viessmann
EM-18/36, EM-50/81, EM-70/115,
BM-36/66, BM-55/88 710-00-0063 7439251
EM 140/207, BM-98/150, BM-123/177 710-00-0064 7439252
Function To mount the CHP module in a higher position (sufcient fresh air inlet from below) for on-site
integration of the exhaust condensate siphon loop/hydraulic seal
Version • Stainless steel channel section
• Length x width x height 1100 /1200 mm x 260 mm x 90 mm
Delivery As loose accessories
2.3.3 Flexible feet
Article number on request
Function With particularly critical foundations and wall bases (e.g. on gravel covers, ceilings with wooden joists),
air-lled damper elements can signicantly attenuate structure-borne noise resulting from the effects of
resonance. The air dampers should be checked regularly on site for the correct lling pressure
Version
Fig. 3 Air-lled damper element
• Elastomer-metal connection with tted oor plate
• Air chamber made from elastomer, reinforced with steel rings
• Air supply via car tyre valve
Delivery As loose accessories
Transport and installation