© 08284 SCU224.monus.indd
5 |
SCU224
S1
S2
S4 / TRF
1.2.2 Wiring connections for system 1
Standard solar system with 1 tank, 1 pump and 3 sensors.
Sensor S4 / TRF can optionally be used for heat quantity
balancing.
R1
Arr 1
S3
1.2.1 Datacommunication/Bus
The controller comes with a VBus
®
for data communication
and energy supply of external modules. The modules are
connected independently of the polarity to the connections
marked with „VBus
®
“. Via this data Bus you can install one
or more VBus
®
modules, e.g.:
• heat quant. measurement module WMZ
• large display GA3
• data logger, DL2
• smart Display SD3
Additionaly, the controller can be connected to the PC with
the help of a USB Adaptor cable. With the Service Center
Software (RCS) the controller parameters can be changed,
measurements can be read out, processed and visualised.
The software enables an easy function control and adjust-
ment of the system.
1 2
S1 S2 S3
3 4 5 6
Temp. Sensor Pt1000
LNR1NR2N
201918171615
S4
7 8
141312
DE - 45527 Hattingen
DeltaSol BS Plus
2 (1) A 115
2
V~
(1) A 115 V~
R1
R2
T4A
115 V~
CU 72060171 01
UL 60730-1A:2002
CSA E60730.1:2002
VBus
910
VBus
connection terminals
Symbol Specification
S1 Collector sensor
S2 Tank sensor below
S3 Tank sensor at the top
(optionally)
S4 / TRF Sensor for heat quantity
measurement (optionally)
R1 Solar pump