13 |
SCU224
4. Control parameter and indication channels
4.1 Channel-overview
Legend:
x
Corresponding channel is available.
x*
Corresponding channel is available if the appropriate option
is activated.

Corresponding channel is only available if the option heat
quantity measurement is activated (OHQM).
MEDT
The channel antifreeze content (MED%) is only shown
if the antifreeze is not water or Tyfocor LS / G-LS
(MEDT 0 or 3). Adjustments concerning the antifreeze
content will only make sense if the antifreeze is used in the
solar circuit.

Corresponding channel is only available if the option heat
quantity measurement is deactivated (OHQM).
Please note:
S3 and S4 are only indicated in case of sensors connected
Channnel
Arr
Specification Page
1 2 3 4 5 6 7 8 9
COL x x x x x x x x Temperature collector 1 15
COL 1 x Temperature collector 1 15
TST x x Temperature tank 1 15
TSTU x x x x Temperature tank 1 below 15
TST1 x x x Temperature tank 1 below 15
TSTO x x x x x Temperature tank 1 at the top 15
TST2 x x x Temperature tank 2 below 15
TFSB x Temperature solid hot fuel boiler 15
TRET x Temperature heating circuit 15
COL2 x Temperature collector 2 15
S3 x Temperature sensor 3 15
TRF
Temperature return sensor 15
S4
x x Temperature sensor 4 15
hP x x x x Operating hours relay 1 16
h P1 x x x x x Operating hours relay 1 16
h P2 x x x x x Operating hours relay 2 16
kWh
Heat quantity kWh 16
MWh
Heat quantity MWh 16
time x Time 15
Arr 1-9 System 12
DT O x x x x x x Switch-on temperature diff 17
DT1O x x x Switch-on temperature diff 1 17
DT F x x x x x x Switch-off temperature diff 1 17
DT1F x x x Switch-off temperature difference 17
S MX x x x x x x Maximum temperature tank 1 17
S1 MX x x x Maximum temperature tank 1 17
DT2O x x x Switch-on temperature difference 2 17
DT2F x x x Switch-off temperature difference 2 17
S2MX x x x Maximum temperature tank 2 17
EM x x x x x x x x emergency temperature collector 1 18
EM1 x emergency temperature collector 1 18